Home arrow Products arrow Spectrometers arrow UV / VIS Spectrometers arrow AvaSpec-3648 High Resolution Fiber Optic Spectrometer





AvaSpec-3648 High Resolution Fiber Optic Spectrometer



The AvaSpec-3648 Fiber Optic Spectrometers is based on the AvaBench-75 symmetrical Czerny-Turner design with 3648 pixel CCD Detector Array. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 16 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range. The AvaSpec-3648 comes with a 16 bit AD converter, and USB2.0 high speed interface. The AvaSpec- 3648 is especially suitable for measuring high resolution applications and, thanks to the 10µs electronic shutter, has a wide dynamic range. An optional  detector coating can enhance the CCD performance for the UV range and a detector collection lens offers high sensitivity.

Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.

The AvaSpec-3648 has a USB2 interface with fast data sampling of 270 spectra per second and data transfer in 3.7 ms  and supports analog in- and outputs as well. Optional Bluetooth® (-BT) communication and an SD card for on-board saving of spectra can be added. The AvaSpec-3648-USB2 runs on USB power and comes with AvaSoft-basic, a complete manual and USB interface cable. Multiple (up to 127) USB2 spectrometers  with different detector types can be externally coupled (see section multi-channel spectrometers).


Technical Data
Optical Bench
Symmetrical Czerny-Turner, 75 mm focal length
Wavelength range
200 - 1100nm
Resolution
0.025 -20 nm, depending on configuration (see table)
Stray light
< 0.1%
Sensitivity (AvaLight-HAL, 8 µm fiber)
14000 counts (16-bit AD)/µW  per ms integration time
Detector
CCD linear array, 3648 pixels
Signal/Noise
350:1
AD converter
16 bit, 1 MHz
Integration time
10 µs - 10 minutes
Interface
USB 2.0 high speed, 480 Mbps
RS-232, 115.200 bps
Sample speed with on-board averaging
3.7 ms / scan
Data transfer speed
3.7 ms / scan (USB2)
750 ms / scan (RS-232)
Digital IO
HD-26 connector, 2 Analog in, 2 Analog out, 3 Digital in, 12 Digital out, trigger, synchronization
Power supply
Default USB power, 350 mA
Or with SPU2 external 12VDC, 350 mA
Dimensions, weight
175 x 110 x 44 mm(1 channel), 716 grams

Grating selection table for AvaSpec-3648

Use
Useable range 
Spectral range (nm)
Lines/mm
Blaze (nm)
Order code
UV/VIS/NIR
200-1100**
900**
300
300
UA
UV/VIS
200-850
520
600
300
UB
UV
200-750
250-220*
1200
250
UC
UV
200-650
165-145*
1800
UV
UD
UV
200-580
115-70*
2400
UV
UE
UV
220-400
70-45*
3600
UV
UF
UV/VIS
250-850
520
600
400
BB
VIS/NIR
300-1100**
800**
300
500
VA
VIS
360-1000
500
600
500
VB
VIS
300-800
250-200*
1200
500
VC
VIS
350-750
145-100*
1800
500
VD
VIS
350-640
75-50*
2400
VIS
VE
NIR
500-1050
500
600
750
NB
NIR
500-1050
220-150*
1200
750
NC
NIR
600-1100**
500**
300
1000
IA
NIR
600-1100
500
600
1000
IB

* depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the smaller the range to select.
**  please note that not all 3648 pixels will be used for the useable range

Resolution table (FWHM) for AvaSpec-3648

Slit size (µm)
Grating (lines/mm)
10
25
50
100
200
500
300
0.5
1.4
2.4
4.3
8.0
20.0
600
0.32
0.7
1.2
2.1
4.1
10.0
1200
0.07-0.13*
0.2-0.3*
0.4-0.6*
0.7-1.0*
1.4-2.0*
3.3-4.8*
1800
0.05-0.08*
0.12-0.21*
0.2-0.36*
0.4-0.7*
0.7-1.4*
1.7-3.3*
2400
0.04-0.07*
0.08-0.15*
0.14-0.25*
0.3-0.5*
0.5-0.9*
1.2-2.2*
3600
0.025-0.04*
0.07-0.10*
0.11-0.16*
0.2-0.3*
0.4-0.6*
0.9-1.4*


 

 

 

 

 

*depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the better the resolution

 


Ordering Information


AvaSpec-3648-USB2 Fiber Optic Spectrometer, 75 mm Avabench, 3648 pixel CCD detector, USB powered high speed USB2 interface, incl. AvaSoft-Basic, USB interface cable, specify grating, wavelength range and options 
   
Options  
-SPU2 incl. switch for USB2 powered or external power for RS-232/BT
-SPU2-BT Bluetooth® interface for USB2 platform only, including antenna and switch
SDXXX  Internal XXX MB SD card for on board data saving, for USB2 platform in combination with DLL only
DUV Deep UV detector coating >150 nm
DCL-UV/VIS Detector Collection Lens to enhance sensitivity, Quartz, 200-1100nm
DLC-UV/VIS-200 Quartz Detector Collection Lens (200-1100nm) for >200 µm fibers 
SLIT-XX   Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
OSF-YYY-3   Order sorting filter for reduction of 2nd order effects, 3 mm thick, please specify YYY= 385, 475, 515, 550, 600 nm
OSC Order sorting coating with 590nm long pass filter for VA, BB (?350nm) and VB gratings in AvaSpec-3648
OSC-UA Order sorting coating with 350 and 590nm longpass filter for UA gratings in AvaSpec-3648
OSC-UB Order sorting coating with 350 and 590nm longpass filter for UB or BB (<350nm) gratings in AvaSpec-3648