AvaLIBS is a novel-design modular system which utilises Laser-Induced Breakdown Spectroscopy (LIBS) for the elemental characterisation of materials. The highly modular and versatile design adopted in AvaLIBS will appeal to scientists and engineers interested in developing LIBS technology for their particular application area. AvaLIBS is also well-suited for use in an academic teaching laboratory where ease of use and safety are of paramount importance.
AvaLIBS may be operated in “open-beam” mode as a Class IV laser system or fitted with one of a range of fully-interlocked modular sample chambers as a Class I laser system. In either configuration the system can be operated with the AvaLIBS Head held or mounted in any orientation offering further flexibility in the types of sample that can be analysed.
Features
- Modular and versatile design, suitable for laboratory and field applications
- High-efficiency plasma light collection optics (3 UV-Vis channels and 3 Vis-NIR channels)
- Laser options: 50 mJ 1064 nm laser (AvaLIBS-50) and 100 mJ 1064 nm laser (AvaLIBS-100)
- Gas purge feature (for connection to external inert gas supply – Argon, Nitrogen, Helium)
- Optional imaging camera for viewing the sample before, during and after LIBS analysis
- May be operated with one of a number of removable, modular sample chambers (to Class I laser safety standards) or without (Class IV “open beam” configuration)
- Optional vertical support stand with height adjustment (facilitates operation of AvaLIBS Head in vertical orientation – with or without sample chamber)
- Up to six spectrometer modules may be installed (approx. 185 – 900 nm)
- External laser power supply easily disconnected to facilitate transportation
- May be operated with laptop PC or other suitable device running Microsoft Windows
System Specifications AvaLIBS base unit
|
AvaLIBS Head
|
Integrated laser beam expander and six-channel plasma light collection optics. Horizontal or vertical operation, connected to Spectrometer console by 1.7 m flexible umbilical containing 6 optical fibers.Approx. dimensions 300x130x120 mm, weight 4 kg
|
|
Software
|
Specline and AvaSoft
|
|
AvaLIBS Spectrometer console(up to 6 spectrometer channels)
|
Contains spectrometers (up to 6), sync cables, USB hub, gas purge inlet (feeds purge gas to AvaLIBS head), laser safety interlock circuit, trigger input to spectrometers.Approx. dimensions 335 x 375 x 160 mm, weight 8 kg
|
|
Computer Interface
|
USB 2.0
|
|
Power connections
|
5VDC, 3A via plug-in adapter 100-240VAC(included)
|
Laser Specifications
| |
YAG-LASER-50
|
YAG-LASER-100
|
|
Laser Type
|
Quantel Big Sky UltraQ-switched Nd: YAG (Class 4)
|
Quantel Big Sky UltraQ-switched Nd: YAG (Class 4)
|
|
Wavelength
|
1064 nm
|
1064 nm
|
|
Energy/Pulse
|
50 mJ/pulse
|
100 mJ/pulse
|
|
Pulse duration
|
7 ns (±2ns)
|
7 ns (±2ns)
|
|
Beam diameter
|
3 mm
|
4 mm
|
|
Repetition Rate
|
Up to 20 Hz
|
Up to 20 Hz
|
|
Power Supply
|
110-220 VAC, 800W
|
110-220 VAC, 800W
|
|
Power supply approx. dimensions, weight
|
360 mm x 435 mm x 140 mm, 14 kg
|
360 mm x 435 mm x 140 mm, 14 kg
|
Spectrometer Specifications
|
Spectrometer
AvaSpec-2048-LIBS1AvaSpec-2048-LIBS2AvaSpec-2048-LIBS3
|
Wavelength range
(185-256nm), FWHM 0.1nm(255-315nm), FWHM 0.1nm(314-316nm), FWHM 0.2nm
|
Spectrometer
AvaSpec-2048-LIBS4AvaSpec-2048-LIBS5AvaSpec-2048-LIBS6
|
Wavelength range
(414-498nm), FWHM 0.2nm(496-718nm), FWHM 0.5nm(716-904nm), FWHM 0.4nm
|
|
Resolution possible
|
< 0.1 nm
|
|
Detector type
|
CCD, 2048 pixels per channel
|
|
Programmable Integration time delay
|
min 1.28 µsec, steps 21 ns
|
|
Integration time
|
Min. 1.1 ms
|
AvaSoft operating software
The AvaSoft software controls the exact timing between the laser pulse and the start of the integration time. The timing is controlled by the laser or external pulse generator and synchronized with the AvaSpec spectrometer by running the spectrometer in external trigger mode. In this mode, the spectrometer receives a TTL-input signal from the laser, or simultaneously with the laser. The integration time delay is synchronized with this input signal.The AvaSoft software allows averaging, setting of integration time delay and integration time.The saved data can be imported directly into the Specline analytical software package (see section software).
Sample chamber Specifications
| |
AvaLIBS-SC-1
|
AvaLIBS-SC-2
|
AvaLIBS-SC-3
|
|
Axis, travel path
|
1 axis, 20mm
|
2 axis, 20 mm each
|
3 axis, 50 mm each
|
|
Approx. dimensions
|
100 x 100 x 200 mm
|
100 x 100 x 250 mm
|
260 x 280 x 320 mm
|
|
Safety protection
|
Electrical interlock to laser power supply, laser protective window, OD 6+
|
AvaLIBS Modules – an alternative method of configuring a LIBS system
AvaLIBS modules offer a convenient and flexible method of configuring a LIBS system. Six channel (AvaLIBS-module-6) and eight channel (AvaLIBS-module-8) versions are available. Each optical channel is connected to an individual spectrometer using a single-core optical fiber. This allows the user to select one or more spectrometers according to their needs. In addition to the 50 mJ and 100 mJ laser described below, the AvaLIBS modules may be used with a variety of other lasers using an appropriate adaptor plate (contact us for further details).
 |
| Example configuration: AvaLIBS-module-8, 100 mJ Ultra laser, AvaLIBS-SC-3 sample chamber, 8 AvaSpec 2048-LIBS spectrometers |
Configuration table
|
AvaLIBS Module configurations
|
50 mJ1-6 channels
|
100 mJ1-6 channels
|
50 mJ1-8 channels
|
100 mJ1-8 channels
|
|
AvaLIBS Module
|
AvaLIBS-module-6
|
AvaLIBS-module-8
|
|
Laser
|
YAG-LASER-50
|
YAG-LASER-100
|
YAG-LASER-50
|
YAG-LASER-100
|
|
Sample chambers
|
Fully compatible with AvaLIBS-SC-1, AvaLIBS-SC-2 and AvaLIBS-SC-3 modular sample chambers
|
Fully compatible with AvaLIBS-SC-1, AvaLIBS-SC-2 and AvaLIBS-SC-3 modular sample chambers
|
|
Fiberoptics
|
N* x FC-UV200-2
|
N* x FC-UV200-2
|
|
Spectrometers
|
Up to 6 spectrometers - as specified by user
|
Up to 8 spectrometers - as specified by user
|
|
Cable set
|
IC-LIBS-SET-N*
|
IC-LIBS-SET-N*
|
N* = number of channels
Ordering Information
|
AvaLIBS-50 and AvaLIBS-100
|
| AvaLIBS-BASE |
AvaLIBS-50 / AvaLIBS-100 head and spectrometer console, including 6 spectrometers, incl. AvaSoft-FULL, excl. laser |
| YAG-LASER-50 |
50mJ Nd:YAG laser, including power supply |
| YAG-LASER-100 |
100mJ Nd:YAG laser, including power supply |
| Imaging kit (optional) |
Miniature CCD colour camera, camera mount, IR blocking filter, plug-in power adaptor, 5.6” LCD colour monitor, USB 2.0 video grabber |
| AvaLIBS-SC-1 |
1-axis sample chamber, couples to AvaLIBS head |
| AvaLIBS-SC-2 |
2-axis sample chamber, couples to AvaLIBS head |
| AvaLIBS-SC-3 |
3-axis sample chamber, couples to AvaLIBS head |
| Vertical support stand (optional) |
Adjustable height vertical support stand for AvaLIBS head |
| AvaLIBS-Specline-A (optional) |
Spectroscopy analytical software for LIBS, finding and identifying spectral lines, incl. database for atoms and ions |
| |
| AvaLIBS Modules |
| AvaLIBS-module-6 |
Six-channel LIBS module, including laser beam expander, plasma light collection optics (6 channels), requires a single-core optical fiber cable to connect each channel to a spectrometer (i.e. 6 fibers required for 6 spectrometers) |
| Adaptor plate for Ultra laser |
For attaching AvaLIBS modules to Ultra laser head (50mJ or 100mJ) |
| Imaging kit (optional) |
Miniature CCD colour camera, camera mount, IR blocking filter, plug-in power adaptor, 5.6” LCD colour monitor, USB 2.0 video grabber |
| Vertical support stand (optional) |
Adjustable height vertical support stand for AvaLIBS-module-6 and AvaLIBS-module-8 |
| FC-UV200-2 |
Fiber Cable, UV/VIS, 2m, SMA terminated (6 or 8 pcs needed) |
| AvaLIBS-module-8 |
Eight-channel LIBS module, including laser beam expander, plasma light collection optics (6 channels), requires a single-core optical fiber cable to connect each channel to a spectrometer (I.e. 8 fibers required for 8 spectrometers) |
| AvaSpec-2048-LIBS |
AvaLIBS Spectrometer channel, Avaspec-2048-USB2, 2048 CCD detector, specify grating, wavelength range and options, AVASOFT-FULL and LIBS |
|