Home arrow Products arrow Application arrow Colorimetry arrow AvaSpec-128 Fiber Optic Spectrometer
PDF





AvaSpec-128 Fiber Optic Spectrometer



The AvaSpec-128 Fiber Optic Spectrometer is the replacement of the AvaSpec-102 and based on the AvaBench-45 symmetrical Czerny-Turner design with 128 pixel Photo Diode Array. The spectrometer has a fiber optic entrance connector (standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 11 different gratings with different dispersion and blaze angles enable applications in the 360-1100nm range. The AvaSpec-128 can be delivered with 2 platforms of electronics; either with USB1.1 with 14 bit AD converter or the new USB2.0 interface with 16 bit AD converter. Applications for this instrument are low cost color measurements. Digital IO ports enable external triggering and control of shutter and pulsed light sources from the Avantes line of instruments.

The AvaSpec-128 is also available as dual channel or multiple channel instrument (up to 8 channels), where all spectra are taken simultaneously.
The AvaSpec-128 comes with AvaSoft-basic, a complete manual, USB interface cable and a PS-12V/1.0A power supply. AvaSoft-full and application software can be ordered separately.
Alternatively the AvaSpec-128-SPU has a switch to run on USB power or external power.
The new AvaSpec128-USB2 has a USB2 interface with ultrafast datasampling of 8000 spectra per second (with on board averaging) and datatransfer in 1.1msec and supports analog in-and outputs as well. Optional Bluetooth ® (-BT) communication and an SD card for on-board saving of spectra can be added. The AvaSpec-128-USB2 runs on USB power and comes with AvaSoft-basic, a complete manual and USB interface cable. Multiple (up to 127) USB2 spectrometers with different detectors can be externally coupled (see section multi-channel spectrometers).

 



Technical Data

Spectrometer platform

AvaSpec-128

AvaSpec-128-USB2

Optical Bench

Symmetrical Czerny-Turner, 45 mm focal length

Wavelength range

360-1100 nm

Resolution

1.2 -64 nm, depending on configuration (see table)

Stray light

< 0.3%

Sensitivity (AvaLight-HAL, 8 µm fiber) in counts/µW  per ms integration time

1000 (14-bit AD)

4000 (16-bit AD)

Detector

Photo diode array, 128 pixels

Signal/Noise

500:1

AD converter

14 bit, 1.33 MHz

16 bit, 2 MHz

Integration time

1 msec - 60 sec

0.06 msec - 10 minutes

Interface

USB 1.1, 12 Mbps

RS-232, 115.200 bps

USB 2.0 high speed, 480 Mbps RS-232, 115.200 bps

Sample speed with on-board averaging

3 msec

0.12 msec

Data transfer speed

6-7 ms / scan (depending on # pixels transferred)

1.1 msec / scan

Digital IO

DB-15 connector, 2 Digital in, 12 Digital out

HD-26 connector, 2 Analog in, 2 Analog out, 3 Digital in, 12 Digital out, trigger, sync.

Power supply

12 VDC, reverse polarity protection ,160 mA (PS-12V/1.0A) or 5VDC USB power

Default USB power, 350 mA

Or with SPU2 external 12VDC, 350 mA

Dimensions, weight

175 x 110 x 44 mm(1 channel), 716 grams

175 x 165 x 85 mm (2 channel), 1.700 grams

175 x 110 x 44 mm(1 channel), 716 grams

 


Grating selection table for AvaSpec-128

Use


Useable range

Spectral range (nm)

Lines/mm

Blaze (nm)

Order code

VIS/NIR

360-1100

500

300

300

UA

VIS

360-750

100

1200

250

UC

VIS

360-850

240

600

400

BB

VIS/NIR

360-1100*

740*

150

500

VZ

VIS/NIR

360-1100

500

300

500

VA

VIS

360-850

240

600

500

VB

VIS

400-980

100

1200

500

VC

NIR

500-935

240

600

750

NB

NIR

500-1000

100

1200

750

NC

NIR

600-1100

500

300

1000

IA

NIR

600-1100

200

600

1000

IB


















* please note that not all 128 pixels will be used for the useable range


Resolution table (FWHM) for AvaSpec-128

Slit size (µm)

Grating (lines/mm)

50

100

200

500

150

13.0

13.0

26.0

64.0

300

6.4

6.4

13.0

32.0

600

3.0

3.0

6.0

16.0

1200

1.5

1.5

3.0

8.0

 

 

 

 

 

 




Ordering Information

AvaSpec-128   Fiber Optic Spectrometer, 45 mm Avabench, 128 pixel PDA detector, USB1.1/RS-232 interface, incl AvaSoft-Basic, USB interface cable and a PS-12V/1.0A power supply,  specify grating, wavelength range and options 
AvaSpec-128-USB2 Fiber Optic Spectrometer, 45 mm Avabench, 128 pixel PDA detector, USB powered high speed USB2 interface, incl AvaSoft-Basic, USB interface cable, specify grating, wavelength range and options
AvaSpec-128-2 Dual Channel Fiber Optic Spectrometer, 2 * 45 mm Avabench, 128 pixel PDA detector, USB1.1/RS-232 interface, incl AvaSoft-Basic, USB interface cable and a PS-12V/1.0A power supply,  for both channels specify grating, wavelength range and options 
   
Options  
-SPU incl. switch for USB powered USB1 or external power for RS232
-SPU2 incl. switch for USB powered USB2 or external power for RS232/BT
-SPU2-BT Bluetooth® interface for USB2 platform only, including antenna and switch
SDXXX  Internal XXX MB SD card for on board data saving, for USB2 platform only
DCL-VIS Detector collection lens to enhance sensitivity, PMMA, 360-1100nm
SLIT-XX   Slit size, please specify XX = 50, 100, 200, 500 µm
OSF-YYY   Order sorting filter for 2nd order effects filtering, please specify YYY= 385, 475, 515, 550, 600 nm