AvaLight-DH-CAL Calibrated Light Source



The AvaLight-DH-CAL is a calibrated light source for the UV/VIS/NIR spectral range (200-1099 nm). This NIST-traceable calibrated light source is developed for use with all AvaSpec spectrometers to measure absolute spectral intensity. The AvaLight-DH-CAL comes with a built-in diffuser, a cosine corrector CC-UV/VIS-CAL with SMA adapter and a CDROM with the calibration file in ASCII format. The software includes two calibration files, both valid for calibration with the cosine corrector. One calibration file can be used for irradiance calibration over the full range (200-1099 nm). In that case both the Deuterium and Halogen light need to be switched on during the calibration.

The other calibration file can be used for irradiance calibration over the VIS/NIR range (350-1099 nm). In that case only the Halogen light needs to be switched on which gives a more smooth and stable output around 656 nm and at the higher wavelengths. Optionally an extended calibration for the NIR spectral range (1100-2500 nm) can be ordered.

The calibration files can be imported in the AvaSoft-IRRAD application software, developed to make your spectrometer system a spectroradiometer.

A special version of the calibrated light source, the AvaLight-DH-CAL-ISPXX, is available to couple the AvaSphere-XX-IRRAD integrating sphere to the light source (XX=30, 50, 80).

The AvaLight-DH-CAL cannot be used as an illumination source for spectral absorbance, transmittance and reflectance  


Technical Data 

Wavelength Range

200-1099 nm / 1100-2500 nm*

Calibration Repeatability

± 1.0%

Calibration Relative Uncertainty to NIST standard

±10% (200-240)
±9% (240-350)
±10% (350-400)
±9.5% (400-1100nm)


 

Calibration valid for

60 hrs  

Warm-up Time

Ca. 30 min.

Bulb Output (CC-UV/VIS-CAL)

80µW/cm2nm (@215nm)

5µW/cm2nm (@800nm)

Power requirement

100-240 VAC

Dimensions (mm)

315 x 165 x 140

*optional extended range NIR calibration

Spectral output AvaLight-HAL-CAL and AvaLight-DH-CAL
hlcaldhcal.jpg

















Ordering Information  
 

AvaLight-DH-CAL

NIST traceable UV/VIS Deuterium/Halogen Lamp with CC-UV/VIS-CAL diffuser, -SR fibers recommended

AvaLight-DH-CAL-ISP30

NIST traceable UV/VIS Deuterium/Halogen Lamp for use with AvaSphere-30-IRRAD, -SR fibers recommended

AvaLight-DH-CAL-ISP50

NIST traceable UV/VIS Deuterium/Halogen Lamp for use with AvaSphere-50-IRRAD, -SR fibers recommended

AvaLight-DH-CAL-ISP80

NIST traceable UV/VIS Deuterium/Halogen Lamp for use with AvaSphere-80-IRRAD, -SR fibers recommended

DH-Recal

AvaLight-DH-CAL recalibration service 200-1099nm

DH-Recal-NIR

AvaLight-DH-CAL extended or recalibration service 1100-2500nm

AvaSoft-IRRAD

Irradiance add-on software, to be ordered with AvaSoft-full