Avantes is excited to release the next generation of AvaSpec-Mini spectrometers with CMOS detectors and advanced electronics and communications. Like the original AvaSpec-Mini, the CL series is only the size of a deck of cards, with excellent temperature and wavelength stability. This instrument is easy to take anywhere you like and is very well suited for handheld applications.

CMOS inside

The AvaSpec-Mini-CL series can be equipped with a 2048-pixel CMOS detector or our first-to-the-market 4096-pixel array. Enjoy the speed and enhanced native UV/NIR response of CMOS with an incredible resolution of up to 0.09 nm unavailable anywhere else. The low stray-light design allows stray-light levels from as low as 0.2%, and the fast response time boasts data transfer speeds as fast as 4.6 ms/scan and integration times ranging from 30 µs to 50 s.

Are you interested in what the AvaSpec-Mini-CL can do for you? Please contact us!

Video

Product Information

Optical bench Symmetrical Czerny-Turner, 75 mm focal length
Wavelength range 200-1100 nm
Stray light 0.2-1%
Sensitivity in counts/µW per ms integration time 337,500
Detector HAM S11639, CMOS linear array, 2048 pixels (14 x 200 µm)
Signal/noise 330:1
AD converter 16 bit, MHz
Integration time 30 µs-40 sec
Interface USB 2.0 (480 Mbps), pigtailed (40 cm) USB-A
Sample speed with on-board averaging 3.0 ms/scan
Data transfer speed 4.6 ms/scan
I/O 5 bidirectional programmable I/O; 1 analog out; 1 analog in, 1 x 5 V
Power supply Default USB connector
Power consumption 225 mA, 5Vdc
Dimensions, weight 95 x 68 x 20 mm, 175 g
Operating temperature range 0-55°C
Use Useable range (nm) Spectral range (nm) Lines/mm Blaze (nm) Order code
UV/VIS/NIR 200-1100** 891** 300 300 MN0300-0.30
UV/VIS 200-850 515 600 300 MN0600-0.30
UV 200-750 247-218* 1200 250 MN1200-0.25
UV 200-650 163-143* 1800 UV MN1800-0.25
UV 200-580 113-69* 2400 UV MN2400-0.25
UV 200-400 69-45* 3600 UV MN3600-0.25
UV/VIS 250-850 515 600 400 MN0600-0.40
VIS/NIR 300-1100** 792** 300 500 MN0300-0.50
VIS 360-1000 495 600 500 MN0600-0.50
VIS 300-800 247-218* 1200 500 MN1200-0.50
VIS 350-750 142-89* 1800 500 MN1800-0.50
VIS 350-640 74-49* 2400 VIS MN2400-0.50
NIR 500-1050 495 600 750 MN0600-0.75
NIR 500-1050 218-148* 1200 750 MN1200-0.75
NIR 600-1160 346-297* 830 800 MN0830-0.80
NIR 600-1100** 495** 300 1000 MN0300-1.00
NIR 600-1100 495 600 1000 MN0600-1.00

A selected set of possible start-stop ranges (recipes) apply. Please contact us to discuss your options.

Slit size (µm) 10 25 50 100 200 500
300 lines/mm grating 1.0 1.4 2.5 4.8 9.2 21.3
600 lines/mm grating 0.40-0.53* 0.7 1.2 2.4 4.6 10.8
830 lines/mm grating 0.32 0.48 0.93 1.7 3.4 8.5
1200 lines/mm grating 0.20-0.28* 0.27-0.38* 0.52-0.66* 1.1 2.3 5.4
1800 lines/mm grating 0.10-0.18* 0.20-0.29* 0.34-0.42* 0.8 1.6 3.6
2400 lines/mm grating 0.09-0.13* 0.13-0.17* 0.26-0.34* 0.44-0.64* 1.1 2.7
3600 lines/mm grating 0.06-0.08* 0.10 0.19 0.4 0.8 1.8

*Depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the higher the resolution.

AvaSpec-Mini2048CL Mini fiber-optic spectrometer, 75 mm focal length, 2048 pixel CMOS detector,USB 2 powered interface, including DCL
SLIT-XX Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
OSC Order sorting coating for grating MN 600-0.50, recommended with OSF-305
OSC-UA Order sorting coating for grating MN 300-0.30
OSC-VA Order sorting coating for grating MN 300-0.50, recommended with OSF-305
OSF-YYY-3 Order sorting filter for reduction of second-order effects, please specify YYY = 305, 395, 457, 515, 550 or 600 nm,ndepends on range