AvaSpec-Mini MK-II (CMOS Inside)

AvaSpec-Mini MK-II (CMOS Inside)
 
||| |||

AvaSpec-Mini(CL): CMOS Inside

Download datasheet

Avantes is excited to release the next generation of AvaSpec-Mini spectrometers with CMOS detectors and advanced electronics and communications. Like the original AvaSpec-Mini, the CL series is only the size of a deck of cards, though with excellent temperature and wavelength stability. This instrument is easy to take anywhere you like, and is very well suited for handheld applications. 

CMOS Inside

The AvaSpec-Mini-CL series can be equipped with a 2048 pixel CMOS detector or the first on the market 4096-pixel array. Enjoy the speed and enhanced native UV/NIR response of CMOS with incredible resolution to 0.1 nm unavailable anywhere else. The low stray light design allows less than 0.2% stray-light and the fast response time boasts data transfer speeds as fast as 4.6 ms/ scan and integrations times ranging from 30µs - 59s.

The First of its Kind 4096 Pixel Mini

One of the most highly anticipated product releases of 2018 is the first on the market 4096 pixel CMOS array, the AvaSpec-Mini4096CL. Witness the incredible resolution of this instrument live at one of our tradeshows in the next months or contact us for more information.

Interested in what the AvaSpec-Mini-CL can do for you? Please contact us!

Technical

  AvaSpec-Mini 2048CL AvaSpec-Mini 4096CL
Optical Bench

Symmetrical Czerny-Turner,
75 mm focal length, MK II

Wavelength range 200-1100 nm 

Stray-light

  <0.2%
                                      

Sensitivity   337.500  261.000
Detector HAM S11639 , CMOS linear
array,
2048 pixels (14x200μm)
HAM S13496 , CMOS linear
array,
4096 pixels (7x200μm)
Signal/Noise 330:1  300:1
AD converter 16 bit, 6 MHz
Integration time 30μs - 50 s
Interface USB 2.0 (480 Mbps) / pigtailed (50cm) USB-A

Sample Speed with
on-board averaging
3.0 ms/scan 6.5 ms/scan 
Data transfer speed 4.6 ms /scan 8.9 ms/scan 
I/O 5 bidirectional programmable I/O; 1 analog out; 1 analog in,
1x5Vz
Power supply Default USB power, 500 mA
Dimensions, weight 95 x 68 x 20 mm, 175 grams
Temperature range 0-550C

 

 

Gratings

Use Useable range (nm) Spectral range (nm) Lines/mm Blaze (nm) Order code
2048 CL          
UV 200-400 167 1800 250 MN 1800-0.25
VIS 330-900 530 600 500 MN 600-0.50
NIR 550-1100 520 600 1000 MN 600-1.00
UV/VIS/NIR 200-1100 900 300 300 MN 300-0.30
VIS/NIR  360-1100 720 300 500  MN 300-0.50
           
4096 CL          
UV 200-400 170 1800 250 MN 1800-0.25
VIS 330-900 535 600 500 MN 600-0.50
NIR 550-1100 525 600 1000 MN 600-1.00
UV/VIS/NIR 200-1100 900 300 300 MN 300-0.30
VIS/NIR 360-1100 720 300 500 MN 300-0.50

Resolutions

Slit size (µm)
2048CL
Grating (lines/mm) 10 25 50 100 200 500
300 1.00 1.30 2.40 4.80 9.20 22.00
600 0.40-0.53 0.70 1.20 2.40 4.60 11.00
1800 0.10-0.18 0.22 0.34-0.42 0.80 1.60 3.60
4096CL
300 0.50-0.70 1.20-1.30 2.17 4.60 9.00 20.00
600 0.30-0.36 0.58-0.60 1.17 2.20 4.50 10.00
1800 0.09-0.11 0.18 0.36-0.40 0.78 1.50 3.70
*Typical values. Small deviations are possible.

Order Info

Ordering Information

AvaSpec-Mini2048CL • Mini Fiber-optic Spectrometer, 75 mm focal length, 2048 pixel CMOS detector,
USB 2 powered interface, including DCL
AvaSpec-Mini4096CL • Mini Fiber-optic Spectrometer, 75 mm focal length, 4096 pixel CMOS detector,
USB 2 powered interface, including DC
Specify grating, wavelength range and options. Other gratings are possible on request.

 

Options

SLIT-XX  
Slit size, please specify XX = 10, 25, 50, 100, 200, 500 µm
OSC   Order sorting coating for grating MN 600-0.50, recommended with OSF-305
OSC-UA Order sorting coating for grating MN 300-0.30
OSC-VA Order sorting coating for grating MN 300-0.50, recommended with OSF-305
OSF-YYY-3 Order sorting filter for reduction of 2nd order effects, please specify YYY= 550 or 600 nm,
depends on range
For non-OEM users a set of preconfigured models are available