For measurements in the near-infrared range up to 1.7 μm, Avantes offers a new series of cooled spectrometer configurations. The AvaSpec-NIR256-1.7-HSC-EVO and the AvaSpec-NIR512-1.7-HSC-EVO offer the high sensitivity100mm optical bench (HSC) with the next generation of electronics (EVO).
Both instruments deliver exceptional performance specifications such as a high sample speed and integration times as fast as 20 μs, as the Avantes instruments you have come to trust.
For applications where resolution is key, or more datapoints for modelling is required, the 512 pixel detector will be the best choice.
The AvaSpec-NIR256/512-1.7-HSC-EVO spectrometers pair the same trusted InGaAs array detectors with our ultra low-noise electronics board, featuring a USB3 and Giga-Ethernet connection port. The instruments are equipped with a Replaceable Slit. Digital and analog I/O ports enable external triggering and control over the shutter and pulsed light sources. Choose from two distinct software-controlled gain-setting modes: high-sensitivity mode (HS, default) and the low-noise mode (LN).
Cooling ensures optimal noise conditions, even at longer integration times. All NIR-1.7 instruments are available with a choice of four different gratings, making it possible to choose the bandwidth fitting your application.
Product Information
-
Gratings
-
Gratings
-
Resolution
-
Ordering Information
-
Options
|
AvaSpec-NIR256-1.7-HSC-EVO |
AvaSpec-NIR512-1.7-HSC-EVO |
Optical bench |
Symmetrical Czerny-Turner, 100 mm focal length, 1 stage TE cooled |
|
Wavelength range |
900 – 1750 nm |
|
Resolution |
1.9-32 nm |
1.7-32 nm |
Stray light |
<1% |
|
Sensitivity HS in counts/µW per ms integration time |
4,800.000 (integral 1000-1750 nm) |
2,500,000 (integral 1000-1750 nm) |
Dynamic range HS |
4900:1 |
|
Signal/noise HS |
1900:1 |
|
Integration time HS |
20 µs-500 ms |
|
Sensitivity LN in counts /µW per ms integration time |
160,000 (integral 1000-1750 nm) |
83,000 (integral 1000-1750 nm) |
Dynamic range LN |
7600:1 |
|
Signal/noise LN |
5000:1 |
|
Integration time LN |
20 µs-20 seconds |
|
Detector |
TE-cooled InGaAs linear array, 256 pixels, 50 µm x 500 µm |
TE-cooled InGaAs linear array, 512 pixels, 25 µm x 500 µm |
AD converter |
16 bit, 1.2 MHz |
|
Interface |
USB 3.0 high speed, 5 Gbps, Gigabit Ethernet 1 Gbps |
|
Sample speed with store to RAM |
0.13 ms/scan |
0.24 ms/scan |
Data transfer speed |
0.4 ms/scan (USB3) |
0.53 ms/scan (USB3) |
Digital IO |
HD-26 connector, 2 Analog in, 2 Analog out, 13 Digital IO bi-directional, trigger, synchronization, strobe, laser |
|
Power supply |
12 VDC, 12 W |
|
Operating temperature range |
0-40°C |
|
Cooling |
24°C |
|
Dimensions, weight |
185 x 160 x 184 mm, 3.6 kg |
|
|
Use |
Spectral range (nm) |
Lines/mm |
Blaze (nm) |
Order code |
NIR |
900-1700 |
790* |
150 |
1250 |
NIR150-1.2 |
NIR |
900-1700 |
380-310* |
300 |
1200 |
NIR300-1.2 |
NIR |
900-1700 |
262-230* |
4001200 |
1200 |
NIR400-1.2 |
NIR |
960-1700 |
262-230* |
400 |
1600 |
NIR400-1.6 |
NIR |
960-1700 |
172-142* |
600 |
1200 |
NIR600-1.2 |
*Depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the smaller the range to select
Slit size (µm) |
25* |
50 |
100 |
200 |
500 |
150 lines/mm grating |
4.0 |
5.7 |
7.0 |
12.8 |
32 |
300 lines/mm grating |
1.8 |
2.3 |
3.0 |
4.0 |
10 |
400 lines/mm grating |
1.7 |
1.9 |
2.5 |
3.3 |
8.3 |
600 lines/mm grating |
0.88 |
1.1 |
1.6 |
2.5 |
6.0 |
*Only available for AvaSpec-NIR512
SLIT-XX-RS |
Replaceable slit with SMA connector, specify slit size XX=25*, 50, 100, 200 or 500 µm |
SLIT-XX-RS-FCPC |